{"product_id":"dc93-00154a-samsung-dryer-heating-element-assembly","title":"DC93-00154A Dryer Heating Element Assembly with Housing Hi-Limit Thermostat and Thermal Fuse Replacement for Samsung Electric Dryers","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e DC93-00154A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Reference Numbers:\u003c\/strong\u003e DC97-14486E, DC47-00032A (inner coil only), 3282568, AP5582094, PS4216214, EAP4216214, PD00002235\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePre-Installed Controls:\u003c\/strong\u003e L260-50F Hi-Limit Thermostat (DC47-00018A style), DC96-00887A Thermal Fuse\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWire Type:\u003c\/strong\u003e \u003cstrong\u003e3-wire heater canister\u003c\/strong\u003e (if your old unit has 2 wires to the coil, use DC97-14486A instead)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment:\u003c\/strong\u003e Samsung front load \u003cstrong\u003eelectric\u003c\/strong\u003e dryers only (DV42H \/ DV45K \/ DV48J \/ DV50K \/ DV52J \/ DVE45 \/ DVE50 \/ DVE52 \/ DVE54 \/ DVE60 series and more; partial list below)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Aftermarket complete heater assembly built to OEM-style specs (not a Genuine Samsung OEM part unless stated in title)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Drop-In Canister\u003c\/strong\u003e — galvanized metal duct housing, 8-coil nickel-chromium heating element, pre-mounted hi-limit thermostat and thermal fuse, no loose parts to transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003e240V 3700W Rating\u003c\/strong\u003e (1500W at 120V leg), 3-wire spade connection to the board, restores full heat on dual-voltage Samsung electric dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eL260-50F Hi-Limit Thermostat\u003c\/strong\u003e cuts power at 260F and resets 50F lower to stop overheating and scorched clothes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eDC96-00887A Non-Resettable Thermal Fuse\u003c\/strong\u003e trips at 320F to prevent fire if airflow is blocked\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eApprox Size 19-1\/2 x 5-1\/8 x 7-3\/4 inches\u003c\/strong\u003e with 5 inch round duct opening one end and 5-1\/2 x 3-3\/4 inch rectangular opening the other, matches original Samsung rear heater box\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eFixes No-Heat and Low-Heat Complaints\u003c\/strong\u003e caused by open coil, blown fuse, stuck thermostat or cracked ceramic supports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eTool Light Install\u003c\/strong\u003e after rear panel removal, uses original mounting screws and spade connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat It Fixes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplace your DC93-00154A heater assembly if you see:\u003c\/p\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eDrum turns but no heat at all\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eHeat for a few minutes then shuts off\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eClothes take two or three cycles to dry\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eThermal fuse keeps blowing after replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eMultimeter shows open continuity on the old coil or fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eOld heater canister has 3 wires to the element coil (not 2)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Samsung Electric Dryer Models (Partial List)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDV42H5600EF\/A3, DV42H5600EP\/A3, DV42H5600EW\/A3, DV45H6300EG\/A3, DV45H6300EW\/A3, DV45K6200EW\/A3, DV45K6200EZ\/A3, DV45K6500EV\/A3, DV45K6500EW\/A3, DV45K7100EW\/A3, DV45K7600EW\/A3, DV48J7700EW\/A2, DV48J7770EP\/A2, DV48J7770EW\/A2, DV50K7500EV\/A3, DV50K7500EW\/A3, DV50K8600EV\/A3, DV50K8600EW\/A3, DV511AER\/XAA, DV511AEW\/XAA, DV520AEP\/XAA, DV520AEW\/XAA, DV52J8700EP\/A2, DV52J8700EW\/A2, DVE45A6400V\/A3, DVE45A6400W\/A3, DVE45M5500P\/A3, DVE45M5500W\/A3, DVE45M5500Z\/A3, DVE45R6300C\/A3, DVE45R6300P\/A3, DVE45R6300V\/A3, DVE45R6300W\/A3, DVE50A8500V\/A3, DVE50A8600E\/A3, DVE50A8600V\/A3, DVE50A8800V\/A3, DVE50R8500V\/A3, DVE50R8500W\/A3, DVE52M7750V\/A3, DVE52M7750W\/A3, DVE52M8650V\/A3, DVE52M8650W\/A3, DVE54M8750V\/A3, DVE54M8750W\/A3, DVE54R7200V\/A3, DVE54R7200W\/A3, DVE54R7600C\/A3, DVE54R7600V\/A3, DVE54R7600W\/A3, DVE55A7300E\/A3, DVE55A7300V\/A3, DVE55A7700V\/A3, DVE55M9600V\/A3, DVE55M9600W\/A3, DVE60A9900V\/A3, DVE60M9900V\/A3, DVE60M9900W\/A3, DVG60M9900V\/A3, WH46DBH100EWA3, WH46DBH500EVA3, WH53DBH700EFA3 and more\u003c\/p\u003e\n\u003cp\u003eIf your exact model is not listed, send us your dryer model number and confirm it is \u003cstrong\u003eelectric (not gas)\u003c\/strong\u003e and the old heater has \u003cstrong\u003e3 wires\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Fitment Note\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDC93-00154A is the \u003cstrong\u003e3-wire\u003c\/strong\u003e Samsung heater canister. If your original assembly has \u003cstrong\u003e2 wires\u003c\/strong\u003e going to the heating coil, you need \u003cstrong\u003eDC97-14486A\u003c\/strong\u003e (2-wire variant), not this part. Always photograph the old thermostat terminal count and wire count before buying.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003ePart Number: \u003cstrong\u003eDC93-00154A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eProduct Type: Dryer Heating Element Assembly with Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eVoltage and Wattage: 240V 3700W (1500W at 120V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eCoil: Nickel-chromium ceramic-insulated 8-coil, DC47-00032A inner element\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eMounted Controls: L260-50F hi-limit thermostat, DC96-00887A thermal fuse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eMaterial: Galvanized steel housing, ceramic terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eApprox Size: 19-1\/2 x 5-1\/8 x 7-3\/4 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003eTerminals: 3-wire spade connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cp\u003ePackage: 1 x Heater assembly (thermostat and fuse pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation and Safety Note\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e Turn off power at the breaker panel and lock it out before removing the rear panel. Photograph every wire position before disconnecting. Unbolt the old canister from the blower duct, lift it out, seat the new DC93-00154A assembly on the original gasket surface, reuse the original screws, reconnect spades exactly as photographed, then restore power and run a timed heat cycle to confirm recovery. If the new thermal fuse blows again, stop and check the exhaust vent for blockage before reordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Disclaimer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an aftermarket replacement assembly. Samsung model names are used only to indicate compatibility. Not affiliated with or endorsed by Samsung Electronics.\u003c\/p\u003e","brand":"Aibopart","offers":[{"title":"Default Title","offer_id":52125331456298,"sku":null,"price":1000.0,"currency_code":"CNY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1001\/5742\/3914\/files\/dc93-00154a-samsung-dryer-hi-limit-thermostat-dc96-00887a-thermal-fuse.jpg?v=1784969836","url":"https:\/\/www.aibopart.com\/products\/dc93-00154a-samsung-dryer-heating-element-assembly","provider":"My Store","version":"1.0","type":"link"}